We are a leading Manufacturer of single phase electronic starters, single phase electrical starter, single phase motor pump starter, single phase starter with analog volt and ammeter, prime single phase digital starter and single phase motor starter from Ahmedabad, India.
Single Phase Electronic Starters
Get Best Quote
Approx. Price: Rs 5,500 / PieceGet Latest Price
We are providing to our valued customers a supreme quality range of Single Phase Electronic Starters. These starters are designed using quality raw material procured from dependable vendors of the market in adherence with international quality standards. We offer these in different specifications at industry leading prices to our clients.
Being one of the reputed organizations in this sector, we are occupied in offering our client with quality assured Single Phase Electrical Starter. The manufacturing process of the offered starter is conducted under the guidance of our skilled professionals by implementing latest machines, technology and premium quality raw material.
Features:
Easy installation
High strength
Long service life
Quality assured
Features And Protections:
Electronic starter
Electronic overload.
Remote sensing dry run / No load current.
Starting capacitor cut off timer ( CCT ).
Extreme high current (EHC) or short circuit more than 24 amps.
Graded internal setting for overload tripping as per current range.
Starting winding protection during pump running.
Technology:
Microcontroller based digital product with high reliability and long life.
World class MCU and software which is highly fault tolerant to noise and Electro magnetic interferences and noise from motor, starter etc.
Produced in ISO 9001: 2000 certified company.
Control Settings:
Pump current setting is easy, accurate, auto setting type, with digital display.
Pump current setting range is 1-16 amps.
Dry run setting from 75 to 95 % in increment of 1 % amps.
Monitoring:
Calibrated Digital Voltmeter with 100 to 300 volt ± 2 volt. Accuracy.
Calibrated Digital Ammeter 0.5 to 26 amps ± 0.2 amps Accuracy.
Digital display for fault ampere at tripping.
In built memory to show last setting value.
On site AUTO FAULT DETECT (AFT) for AC voltage, LEDS, Display, Relay, etc.
Timers:
Digital display for countdown timer.
Time delay to filter power on spikes and surges.
Capacitor cut off timer to protect starting capacitor.
Additional Features:
Starting (1) and running capacitors (2) as per pump requirements.
Site selectable auto / manual operation facility.
Widest working voltage range from 140 to 300 volts.
Specially made heavy duty air sealed 40 amps dc coil contactor for long life.
Color coded ISI grade copper wiring with lugs for longer life.
Modular design very easy to install and site servicing.
Emergency bypass for water level controller.
Request Callback
Yes! I am interested
Single Phase Motor Pump Starter
Get Best Quote
Approx. Price: Rs 5,000 / PieceGet Latest Price
Product Details:
Phase
Single Phase
Starter Type
Single Phase Starter
Brand
Any
Our firm is offering Single Phase Motor Pump Starter to our esteemed consumers. Widely renowned among our clients for superior performance, the offered product is developed by our team of expect in our sophisticated production unit utilizing all the latest tools and techniques. Client can avail the same from us at economical prices.
Features:
Compact construction
Optimum performance
Weather proof body
Overload and dry run cut off limit
Features And Protections:
Electronic starter
Electronic overload.
Remote sensing dry run / No load current.
Starting capacitor cut off timer ( CCT ).
Extreme high current (EHC) or short circuit more than 24 amps.
Graded internal setting for overload tripping as per current range.
Starting winding protection during pump running.
High voltage
Low voltage
Fully automatic two tank water level controller.
Starting winding protection during pump running.
Technology:
Microcontroller based digital product with high reliability and long life.
World class MCU and software which is highly fault tolerant to noise and Electro magnetic interferences and noise from motor, starter etc.
Produced in ISO 9001: 2000 certified company.
Control Settings:
Pump current setting is easy, accurate, auto setting type, with digital display.
Pump current setting range is 1-16 amps.
Dry run setting from 75 to 95 % in increment of 1 % amps.
Dry run bypass facility with digital display.
Site selectable Auto / Manual operation switch for panel.
Site selectable Auto / bypass operation switch for level controller.
Monitoring
Calibrated Digital Voltmeter with 100 to 300 volt ± 2 volt. Accuracy.
Calibrated Digital Ammeter 0.5 to 26 amps ± 0.2 amps Accuracy.
Digital display for fault ampere at tripping.
In built memory to show last setting value.
On site AUTO FAULT DETECT (AFT) for AC voltage, LEDS, Display, Relay, etc.
Timers:
Site settable Dry run auto start timer from 10 to 720 minutes with timer OFF facility.
Digital display for countdown timer (Model KDP 99).
On delay timer of 1 minute for auto start at power failure in auto mode.
Time delay to filter power on spikes and surges.
In built time compensation due to power failure during dry run auto start timer i.e. timer will start from same time once power returns.
Capacitor cut off timer to protect starting capacitor.
Additional Features:
Starting (1) and running capacitors (2) as per pump requirements.
Water level control is universal ie can be connected to float / magnetic switch or metal sensors.
Site selectable auto / manual operation facility.
Widest working voltage range from 140 to 300 volts.
Specially made heavy duty air sealed 40 amps dc coil contactor for long life.
Color coded ISI grade copper wiring with lugs for longer life.
Modular design very easy to install and site servicing.
We are Providing to our valued Customers the best quality range of Prime Single Phase Digital Starter Microcontroller based digital product with high reliability and long life.
Features:
Compact construction
Optimum performance
High strength
Long service life
Features and Protections:
Electronic starter
Electronic overload.
Remote sensing dry run / No load current.
Starting capacitor cut off timer ( CCT ).
Extreme high current (EHC) or short circuit more than 24 amps.
The graded internal setting for overload tripping as per current range.
Starting winding protection during pump running.
Technology:
Microcontroller based digital product with high reliability and long life.
World class MCU and software which is highly faulted tolerant to noise and Electromagnetic interferences and noise from the motor, starter etc.
Produced in ISO 9001: 2000 certified company.
Control Settings:
Pump current setting is easy, accurate, auto setting type, with digital display.
Pump current setting range is 1-16 amps.
Dry run setting from 75 to 95 % in increment of 1 % amps.
Monitoring:
Calibrated Digital Voltmeter with 100 to 300 volt ± 2 volts. Accuracy.
Calibrated Digital Ammeter 0.5 to 26 amps ± 0.2 amps Accuracy.
Digital display for fault ampere at tripping.
In built memory to show last setting value.
On-site Auto Fault Detect (AFT) for AC voltage, LEDS, Display, Relay, etc.
Timers:
Digital display for a countdown timer.
Time delay to filter power on spikes and surges.
Capacitor cut off timer to protect starting capacitor.
Additional Features:
Starting (1) and running capacitors (2) as per pump requirements.
Site selectable auto / manual operation facility.
Widest working voltage ranges from 140 to 300 volts.
Specially made heavy duty air sealed 40 amps Dc coil Contactor for long life.
Color coded ISI grade copper wiring with lugs for longer life.
Modular design very easy to install and site servicing.
Emergency bypass for water level controller.
Request Callback
Yes! I am interested
Single Phase Motor Starter
Get Best Quote
Approx. Price: Rs 4,500 / PieceGet Latest Price
Product Details:
Brand
Siemens, C&S Electric, Any, Larsen & Toubro
Motor Power
Any HP
Features And Protections:
Phase failure / loss.
Phase reversal / wrong phase sequence.
Phase to phase voltage unbalance.
Electronic overload:
Remote sensing dry run / No load current.
Extreme high current (EHC) or short circuit more than 24 amps.
The graded internal setting for overload tripping as per current range.
High / low voltage with Auto Start.
Fully automatic two tank water level controller.
Technology:
Microcontroller based digital product with high reliability and long life.
World class MCU and software which is highly faulted tolerant to noise and Electromagnetic interferences and noise from the motor, starter etc.
Produced in ISO 9001: 2000 certified company.
Control Settings:
DOL Starter up to 7. 5 hp with specially made heavy duty 16 amps L & T type AC coil contactor / or 30 amps Dc coil contactor.
Pump current setting is easy, accurate, auto setting type, with digital display.
Pump current setting range is 1-16 amps
Dry run setting from 75 to 95 % in increment of 1 % amps.
Dry run bypass facility with digital display.
Site selectable Auto / Manual operation switch.
Monitoring:
Calibrated Digital Voltmeter with 200 to 500 volt ± 2 volts. Accuracy.
Calibrated Digital Ammeter 0.5 to 26 amps ± 0.2 amps Accuracy.
Digital display for fault ampere at tripping.
Inbuilt memory to show last setting value.
On-site AUTO FAULT DETECT (AFT) for AC voltage, LEDS, Display, Relay, etc.
Timers:
Site settable Dry run auto starts the timer from 10 to 720 minutes with timer OFF facility.
Digital display for the countdown timer.
On delay timer for one minute for an auto start for power failure and SPP faults.
Time delay to filter power on spikes and surges.
Inbuilt time compensation due to power failure during dry run auto start timer i.e. timer will start from the same time once power returns.
Additional Features:
Site selectable unit bypass facility.
Three pole MCB of 32 amps for short circuit and act as the main switch.
R, Y, B Indicators for three phases.
Water level control is universal die can be connected to float magnetic switch or metal sensors.
Widest working voltage ranges from 200 to 500 volts.
Color coded ISI grade copper wiring with lugs for longer life.
Emergency bypass for water level controller.
Modular design very easy to install and site servicing.