Providing you the best range of ro plant control panel, reverse osmosis plant control automation and ro control panel with gsm controller system with effective & timely delivery.
RO Plant Control Panel
Get Best Quote
Approx. Price: Rs 50 / UnitGet Latest Price
Product Details:
Application
TO CONTROL RO PLANT
Phase
Single Phase
Power
ANY
RO Plant Control Panel
Our enterprise has been counted amidst the leading providers of Reverse Osmosis Plant Control Automation. The offered product is designed and developed using premium quality raw material sourced from reliable vendors of the market. Our team of professionals makes sure that the product goes through various quality tests to ensure that best quality product is delivered to the client.
Features:
Optimum functionality
Less maintenance
Longer working life
High efficiency
Features and Protections:
Electronic starter
Electronic overload.
Remote sensing dry run / No load current.
Starting capacitor cut off timer ( CCT ).
Extreme high current (EHC) or short circuit more than 24 amps.
The graded internal setting for overload tripping as per current range.
Starting winding protection during pump running.
Technology:
Microcontroller based digital product with high reliability and long life.
World class MCU and software which is highly faulted tolerant to noise and Electromagnetic interferences and noise from the motor, starter etc.
Produced in ISO 9001: 2000 certified company.
Control Settings:
Pump current setting is easy, accurate, auto setting type, with digital display.
Pump current setting range is 1-16 amps.
Dry run setting from 75 to 95 % in increment of 1 % amps.
Monitoring:
Calibrated Digital Voltmeter with 100 to 300 volt ± 2 volt.
Accuracy:
Calibrated Digital Ammeter 0.5 to 26 amps ± 0.2 amps Accuracy.
Digital display for fault ampere at tripping.
Inbuilt memory to show last setting value.
On-site Auto Fault Decent (AFT) for AC voltage, LEDS, Display, Relay, etc.
Timers:
Digital display for the countdown timer.
Time delay to filter power on spikes and surges.
Capacitor cut off timer to protect starting capacitor.
Additional Features:
Starting (1) and running capacitors (2) as per pump requirements.
Site selectable auto / manual operation facility.
Widest working voltage ranges from 140 to 300 volts.
Specially made heavy duty air sealed 40 amps dc coil contactor for long life.
Color coded ISI grade copper wiring with lugs for longer life.
Modular design very easy to install and site servicing.
Emergency bypass for water level controller.
Price Range 1500 To 50000 Rs.
Request Callback
Additional Information:
Pay Mode Terms: T/T (Bank Transfer)
Delivery Time: 1 DAY
Yes! I am interested
View PDF
Reverse Osmosis Plant Control Automation
Get Best Quote
Approx. Price: Rs 70 / PieceGet Latest Price
Product Details:
Type
Automatic
Digit Display Size
Single Display
Our enterprise has been counted amidst the leading providers of Reverse Osmosis Plant Control Automation. The offered product is designed and developed using premium quality raw material sourced from reliable vendors of the market. Our team of professionals makes sure that the product goes through various quality tests to ensure that best quality product is delivered to the client.
Features:
Optimum functionality
Less maintenance
Longer working life
High efficiency
Features and Protections:
Electronic starter
Electronic overload.
Remote sensing dry run / No load current.
Starting capacitor cut off timer ( CCT ).
Extreme high current (EHC) or short circuit more than 24 amps.
The graded internal setting for overload tripping as per current range.
Starting winding protection during pump running.
Technology:
Microcontroller based digital product with high reliability and long life.
World class MCU and software which is highly faulted tolerant to noise and Electromagnetic interferences and noise from the motor, starter etc.
Produced in ISO 9001: 2000 certified company.
Control Settings:
Pump current setting is easy, accurate, auto setting type, with digital display.
Pump current setting range is 1-16 amps.
Dry run setting from 75 to 95 % in increment of 1 % amps.
Monitoring:
Calibrated Digital Voltmeter with 100 to 300 volt ± 2 volt.
Accuracy:
Calibrated Digital Ammeter 0.5 to 26 amps ± 0.2 amps Accuracy.
Digital display for fault ampere at tripping.
Inbuilt memory to show last setting value.
On-site Auto Fault Decent (AFT) for AC voltage, LEDS, Display, Relay, etc.
Timers:
Digital display for the countdown timer.
Time delay to filter power on spikes and surges.
Capacitor cut off timer to protect starting capacitor.
Additional Features:
Starting (1) and running capacitors (2) as per pump requirements.
Site selectable auto / manual operation facility.
Widest working voltage ranges from 140 to 300 volts.
Specially made heavy duty air sealed 40 amps dc coil contactor for long life.
Color coded ISI grade copper wiring with lugs for longer life.
Modular design very easy to install and site servicing.
Emergency bypass for water level controller.
Price Range 1500 To 50000 Rs.
Request Callback
Yes! I am interested
RO Control Panel with GSM Controller System
Get Best Quote
Approx. Price: Rs 120 / UnitGet Latest Price
Product Details:
Phase
Three Phase
Power
ANY
RO control Panel With GSM Controller system
Our enterprise has been counted amidst the leading providers of Reverse Osmosis Plant Control Automation. The offered product is designed and developed using premium quality raw material sourced from reliable vendors of the market. Our team of professionals makes sure that the product goes through various quality tests to ensure that best quality product is delivered to the client.
Features:
Optimum functionality
Less maintenance
Longer working life
High efficiency
Features and Protections:
Electronic starter
Electronic overload.
Remote sensing dry run / No load current.
Starting capacitor cut off timer ( CCT ).
Extreme high current (EHC) or short circuit more than 24 amps.
The graded internal setting for overload tripping as per current range.
Starting winding protection during pump running.
Technology:
Microcontroller based digital product with high reliability and long life.
World class MCU and software which is highly faulted tolerant to noise and Electromagnetic interferences and noise from the motor, starter etc.
Produced in ISO 9001: 2000 certified company.
Control Settings:
Pump current setting is easy, accurate, auto setting type, with digital display.
Pump current setting range is 1-16 amps.
Dry run setting from 75 to 95 % in increment of 1 % amps.
Monitoring:
Calibrated Digital Voltmeter with 100 to 300 volt ± 2 volt.
Accuracy:
Calibrated Digital Ammeter 0.5 to 26 amps ± 0.2 amps Accuracy.
Digital display for fault ampere at tripping.
Inbuilt memory to show last setting value.
On-site Auto Fault Decent (AFT) for AC voltage, LEDS, Display, Relay, etc.
Timers:
Digital display for the countdown timer.
Time delay to filter power on spikes and surges.
Capacitor cut off timer to protect starting capacitor.
Additional Features:
Starting (1) and running capacitors (2) as per pump requirements.
Site selectable auto / manual operation facility.
Widest working voltage ranges from 140 to 300 volts.
Specially made heavy duty air sealed 40 amps dc coil contactor for long life.
Color coded ISI grade copper wiring with lugs for longer life.
Modular design very easy to install and site servicing.